4.3.7.3. Allocating the Command Queue
- Allocate memory for the Command queue.
- Program the SMMU_IDR1.CMDQS to maximum number of Command Queue entries.
- Set the command base address by writing SMMU_CMDQ_BASE.ADDR register; write the SMMU_CMDQ_BASE.LOG2SIZE as queue size as log2(entries); LOGSIZE must be less than or equal to CMDQS. The Command queue related registers are given.
- Set the queue read index in SMMU_CMDQ_CONS.RD and queue write index in SMMU_CMDQ_PROD.WR to 0.
Register Name |
Address |
Description |
---|---|---|
SMMU_CMDQ_BASE_LO_ADDR |
0x90 |
Non-secure Command Queue Base Address Low |
SMMU_CMDQ_BASE_HI_ADDR |
0x94 |
Non-secure Command Queue Base Address High |
SMMU_S_CMDQ_BASE_LO_ADDR |
0x8090 |
Secure Command Queue Base Address Low |
SMMU_S_CMDQ_BASE_HI_ADDR |
0x8094 |
Secure Command Queue Base Address High |
SMMU_CMDQ_PROD_ADDR |
0x98 |
Non-secure Command Queue Producer Address |
SMMU_S_CMDQ_PROD_ADDR |
0x8098 |
Secure Command Queue Producer Address |
SMMU_CMDQ_CONS_ADDR |
0x9C |
Non-secure Command Queue Consumer Address |
SMMU_S_CMDQ_CONS_ADDR |
0x809C |
Secure Command Queue Consumer Address |
Commands are submitted to SMMU by writing them to the command queue then after ensuring their visibility to SMMU, updating the SMMU_(S)_CMDQ_PROD.WR index which notifies the SMMU there are commands to process.
The actual commands are processed as part of Queue Table Walk (QTW) over ACE-Lite+DVM interface.