16.4.3.2.1.1. Stream Data Transmit

If the transfer_mode bit in the cmd register is set to 1, the transfer is a stream‑write data transfer. The data path reads data from the FIFO buffer from the BIU and transmits in a stream to the card data bus. If the FIFO buffer becomes empty, the card clock is stopped and restarted once data is available in the FIFO buffer.

If the bytcnt register is reset to 0, the transfer is an open‑ended stream‑write data transfer. During this data transfer, the data path continuously transmits data in a stream until the host software issues an SD/SDIO STOP command. A stream data transfer is terminated when the end bit of the STOP command and end bit of the data match over two clock cycles.

If the bytcnt register is written with a nonzero value and the send_auto_stop bit in the cmd register is set to 1, the STOP command is internally generated and loaded in the command path when the end bit of the STOP command occurs after the last byte of the stream write transfer matches. This data transfer can also terminate if the host issues a STOP command before all the data bytes are transferred to the card bus.