Intel® Stratix® 10 Hard Processor System Technical Reference Manual

ID 683222
Date 11/28/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

23.3.1. Clocks

Table 212.  Timers Clock Characteristics

Timers

System Clock

Notes

System timer 0

sys_timer0 l4_sys_free_clk

_

System timer 1

sys_timer1

SP timer 0

sp_timer0 l4_sp_clk

Timers must be disabled if clock frequency changes

SP timer 1

sp_timer1

The timers above are labeled according to the clock they receive. The system timers are connected to the L4_SYS bus and clocked by the l4_sys_free_clk. The SP timers are connected to the L4_SP bus and clocked by l4_sp_clk.

SP timer 0 and SP timer 1 must be disabled before l4_sp_clk is changed to another frequency. You can then re-enable the timer once the clock frequency change takes effect.