Intel® Stratix® 10 Hard Processor System Technical Reference Manual

ID 683222
Date 11/28/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

16.5.5.3. Data Transfer Interrupts

The controller generates an interrupt for different conditions during data transfer, which are reflected in the following rintsts register bits:
  1. dto—Data transfer is over or terminated. If there is a response timeout error, the controller does not attempt any data transfer and the Data Transfer Over bit is never set.
  2. Transmit FIFO data request bit (txdr)—The FIFO buffer threshold for transmitting data is reached; software is expected to write data, if available, into the FIFO buffer.
  3. Receive FIFO data request bit (rxdr)—The FIFO buffer threshold for receiving data is reached; software is expected to read data from the FIFO buffer.
  4. hto—The FIFO buffer is empty during transmission or is full during reception. Unless software corrects this condition by writing data for empty condition, or reading data for full condition, the controller cannot continue with data transfer. The clock to the card is stopped.
  5. bds—The card has not sent data within the timeout period.
  6. dcrc—A CRC error occurred during data reception.
  7. sbe—The start bit is not received during data reception.
  8. ebe—The end bit is not received during data reception, or for a write operation. A CRC error is indicated by the card.

dcrc, sbe, and ebe indicate that the received data might have errors. If there is a response timeout, no data transfer occurs.