GTS Ethernet Intel® FPGA Hard IP User Guide

ID 817676
Date 8/05/2024
Public
Document Table of Contents

7.3.2. Simulator Output

The following sample output illustrates a successful simulation test run of the 10GE Ethernet with SyncE enabled in QuestaSim simulator. The script and waveform output is similar for other supported simulators.
---TX reset sequence completed -----
# The time now is 40000000000 
# ---RX reset sequence completed -----
# The time now is 50000000000 
# 
# ---IP_INST[  0] Test    0;  ---Total 16 packets to send-----
# ------IP_INST[0] Start pkt gen TX-----
# ------Checking Packet TX/RX result-----
# ------2 packets Sent;     0 packets Received--------
# ---- 16 packets Sent;    16 packets Received--------
# ------ALL   16  packets Sent out---
# ------ALL   16  packets Received---
# ------TX/RX packet check OK---
# 
# ****Starting AVMM Read/Write****
# ====>MATCH!  Read addr = 00000104, ReaddataValid = 1 Readdata = abcdef01 Expected_Readdata = abcdef01 
# 
# The time now is 60000000000 
# 
# ====>MATCH!  Read addr = 00000108, ReaddataValid = 1 Readdata = 00000007 Expected_Readdata = 00000007 
# 
# ====>MATCH!  Read addr = 00100004, ReaddataValid = 1 Readdata = b1f05663 Expected_Readdata = b1f05663 
# 
# ====>MATCH!  Read addr = 00100008, ReaddataValid = 1 Readdata = 06b97b0d Expected_Readdata = 06b97b0d 
# 
# ====>MATCH!  Read addr = 00100080, ReaddataValid = 1 Readdata = deadc0de Expected_Readdata = deadc0de 
# 
# ====>MATCH!  Read addr = 00300080, ReaddataValid = 1 Readdata = deadc0de Expected_Readdata = deadc0de 
# 
# ====>MATCH!  Read addr = 00000af0, ReaddataValid = 1 Readdata = 00000000 Expected_Readdata = 00000000 
# 
# ====>MATCH!  Read addr = 00050014, ReaddataValid = 1 Readdata = 22334455 Expected_Readdata = 22334455 
# 
# ====>MATCH!  Read addr = 0005001c, ReaddataValid = 1 Readdata = 000005ee Expected_Readdata = 000005ee 
# 
# ====>MATCH!  Read addr = 00050014, ReaddataValid = 1 Readdata = 01234567 Expected_Readdata = 01234567 
# 
# ====>MATCH!  Read addr = 00050018, ReaddataValid = 1 Readdata = 000089ab Expected_Readdata = 000089ab 
# 
# ====>MATCH!  Read addr = 000a5000, ReaddataValid = 1 Readdata = 00000000 Expected_Readdata = 00000000 
# 
# **** AVMM Read/Write Operation Completed for IP_INST[  0]****
# ** Testbench complete
# ****************************************

The following sample waveform illustrates a simulation test run of the 10GE Ethernet with SyncE enabled in QuestaSim simulator.