Hard Processor System Technical Reference Manual: Agilex™ 5 SoCs

ID 814346
Date 4/01/2024
Public
Document Table of Contents

6.1. System Manager Differences Among Intel SoC Device Families

Table 287.  HPS System Manager Differences
System Manager Feature

Cyclone® V SoC,

Arria® V SoC

Arria® 10 SoC

Stratix® 10 SoC,

Intel® Agilex™ 7

F-Series/I-Series/

M-Series SoC

Agilex™ 5

E-Series/D-Series SoC

Injects errors to ECC-protected peripherals Yes No 26 No26 No26
Boot scratch space 10 registers on cold reset domain 10 registers on cold reset domain 10 registers on cold reset domain

10 registers on cold reset domain

10 registers on warm reset domain

10 registers on POR reset domain
26 In the Arria® 10, Stratix® 10, Agilex™ 7, and Agilex™ 5 device families, the ECC controller performs this function.