Hard Processor System Technical Reference Manual: Agilex™ 5 SoCs

ID 814346
Date 4/01/2024
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

5.3.6.10. Controller Fixed Parameters and Clock Frequencies Supported

This section provides configuration parameters for which the NAND Controller has been pre-configured. This includes overall parameters in the NAND controller and some internal components.

Table 209.  Fixed Parameters Used in the NAND Flash Controller
Parameter Value
Master and Slave Data Port Address Bus Width AXI4 64 bits
Master and Slave Data Port Data Bus Width AXI4 64 bits
Maximum Page Size in Flash Device 64 KB
Context Storage RAM - SPRAM 64bits x 80 words = 5120 bits
Records Table storage RAM - SPRAM 68 bits x 1024 words = 69632 bits
TX FIFO RAM - DPRAM (64 data bits + 8 parity) x 128 words = 9216
nf_clk Clock

This clock drives the mini controller and PHY modules.

Min: 20 MHz Max: 400MHz.

bch_clk Clock22

This clock drives the controller's BCH engine. The bch_clk frequency depends on the BCH configuration and should be trimmed depending on the BCH engine paralleling factors and the nf_clk clock frequency value.

Min: 20 MHz Max: 400MHz

sys_clk Clock22

This clock drives most of the controller logic except ECC, the minicontroller, and SFR interface modules. Its frequency should match the host interface clock frequency.

Min: 20 MHz Max: 400MHz

sfr_clk Clock22

This clock drives the controller’s slave register port. It allows the register interface to operate at lower speed.

Min: 1 MHz Max: 400MHz (must be lower than or equal to sys_clk)

dphy_reg_clk Clock22

This clock drives the controller’s PHY register port. It allows the controller and PHY register interfaces to operate at lower speed.

Min: 20 MHz Max: 400MHz

NAND Controller Reset The NAND Flash controller receives a single nand_flash_rst_n signal from the reset manager.
Note:
22 All clock modifications to the controller should be done only when the controller is in the IDLE state. The controller’s IDLE state can be determined if the ctrl_busy pin or the ctrl_busy bit in the ctrl_status (0x0118) register has gone low.