14.6.8. ECC Controller Clocks

The ECC controller for each ECC-protected memory operates at the same clock frequency as its associated RAM port.

The ECC register interface, however, is in the l4_mp_clk domain. The clock source names for each ECC controller and its RAM are determined by the specific peripheral.

Table 394.   Clock Source for Each ECC Controller and Memory

ECC Memory

Functional Clock

On-chip RAM

l3_main_free_clk

USB

asynchronous l4_mp_clk

Ethernet MAC (Rx FIFO)

Read: ap_clk
Write: clk_rx_int

Ethernet MAC (Tx FIFO)

Read: ap_clk
Write: clk_tx_int