22.4.3.2. Automatic RTS mode

Automatic RTS mode becomes active when the following conditions occur: †

  • RTS (MCR.RTS bit and MCR.AFCE bit are both set)
  • FIFO buffers are enabled (FCR.FIFOE bit is set)

With automatic RTS enabled, the rts_n output pin is forced inactive (high) when the FIFO is almost full; where "almost full" refers to two available slots in the FIFO. When rts_n is connected to the cts_n input pin of another UART device, the other UART stops sending serial data until the receive FIFO buffer has available space (until it is completely empty). †

The selectable receive FIFO buffer threshold values are 1, ¼, ½, and 2 less than full. Because one additional character may be transmitted to the UART after rts_n is inactive (due to data already having entered the transmitter block in the other UART), setting the threshold to 2 less than full allows maximum use of the FIFO buffer with a margin of one character. †

Once the receive FIFO buffer is completely emptied by reading the receiver buffer register (RBR_THR_DLL), rts_n again becomes active (low), signaling the other UART to continue sending data.†

Even when you set the correct MCR bits, if the FIFO buffers are disabled through FCR.FIFOE, automatic flow control is also disabled. When auto RTS is not implemented or disabled, rts_n is controlled solely by MCR.RTS. In the Automatic RTS Timing diagram, the character T is received because rts_n is not detected prior to the next character entering the sending UART transmitter. †

Figure 141. Automatic RTS Timing