4.2.3. Reset and Initialization

Software is responsible for transitioning each structural unit into the operational state, and then responsible for transitioning into the online state.
  • Transition the directory to the online state.
  • Transition the Coherent Memory Interface (CMI) to the online state.
  • Transition the non-coherent bridge to the online state.
  • Transition the Coherent Agent Interface (CAI) to the online state.