15.5.2.1.1. Single Block Erase

A single command is needed to complete a single‑block erase, as follows:
  1. Write to the command register, setting the CMD_MAP field to 2 and the BLK_ADDR field to the desired erase block.
  2. Write 0x01 to the Data register.

For a single block erase, the register multiplane_operation in the config group must be reset.

After the device completes the erase operation, the controller generates an erase_comp interrupt. If the erase operation fails, the erase_fail interrupt is issued. The failing block's address is updated in the err_block_addr0 register in the status group.