Visible to Intel only — GUID: mnv1726178382650
Ixiasoft
1. Introduction
2. Features
3. Getting Started with GTS AXI Streaming IP
4. IP Architecture and Functional Description
5. IP Parameters
6. Interfaces and Signals
7. Registers
8. Document Revision History for the GTS AXI Streaming Intel® FPGA IP for PCI Express* User Guide
A. Troubleshooting/Debugging
B. PIPE Mode Simulation
C. Implementation of Address Translation Services (ATS) in Endpoint Mode
3.1. Downloading and Installing Quartus® Prime Software
3.2. Configuring and Generating the GTS AXI Streaming IP
3.3. Configuring and Generating GTS System PLL Clocks Intel® FPGA IP
3.4. Configuring and Generating GTS Reset Sequencer Intel® FPGA IP
3.5. Instantiating and Connecting GTS AXI Streaming IP Interfaces (and Other IPs)
3.6. Simulating the GTS AXI Streaming IP Variant
3.7. Compiling the GTS AXI Streaming IP Variant
4.1. Clocking
4.2. Resets
4.3. PCIe* Hard IP
4.4. Hard IP Interface (IF) Adaptor
4.5. Interrupts
4.6. Transaction Ordering
4.7. TX Non-Posted Metering Requirement on Application
4.8. AXI4-Stream Interface
4.9. Tag Allocation
4.10. Power Management
4.11. Config Retry Status Enable
4.12. Hot-Plug
4.13. Configuration Space Extension
4.14. Page Request Service (EP only)
4.15. Precision Time Measurement (PTM)
4.16. Single Root I/O Virtualization (SR-IOV)
4.17. Transaction Layer Packet (TLP) Bypass Mode
4.18. Scalable IOV
5.2.2.3.1. PCIe0/PCIe1 Device
5.2.2.3.2. PCIe0/PCIe1 Link
5.2.2.3.3. PCIe0/PCIe1 Slot
5.2.2.3.4. PCIe0/PCIe1 Legacy Interrupt Pin Register
5.2.2.3.5. PCIe0/PCIe1 PTM
5.2.2.3.6. PCIe0/PCIe1 LTR
5.2.2.3.7. PCIe0/PCIe1 MSI
5.2.2.3.8. PCIe0/PCIe1 MSI-X
5.2.2.3.9. PCIe0/PCIe1 PASID
5.2.2.3.10. PCIe0/PCIe1 DEV SER
5.2.2.3.11. PCIe0/PCIe1 PRS
5.2.2.3.12. PCIe0/PCIe1 Power Management
5.2.2.3.13. PCIe0/PCIe1 VSEC
5.2.2.3.14. PCIe0/PCIe1 ATS
5.2.2.3.15. PCIe0/PCIe1 TPH
5.2.2.3.16. PCIe0/PCIe1 ACS
5.2.2.3.17. PCIe0/PCIe1 Hot-Plug
5.2.2.3.18. PCIe0/PCIe1 VIRTIO
6.1. Overview
6.2. Clocks and Resets
6.3. AXI4-Stream Interfaces
6.4. Configuration Intercept Interface
6.5. Configuration Extension Bus (CEB) Interface
6.6. Control Shadow Interface
6.7. Transmit Flow Control Credit Interface
6.8. Completion Timeout Interface
6.9. Control and Status Register Responder Interface
6.10. Function Level Reset Interface
6.11. TLP Bypass Error Reporting Interface
6.12. Error Interface
6.13. VF Error Flag Interface
6.14. VIRTIO PCI* Configuration Access Interface
6.15. Precision Time Measurement (PTM) Interface
6.16. Serial Data Signals
6.17. Miscellaneous Signals
7.6.1. VF PCI-Compatible Configuration Space Header Type0
7.6.2. VF PCI Express* Capability Structure
7.6.3. VF Message Signal Interrupt Extended (MSI-X) Capability Structure
7.6.4. VF Alternative Routing ID (ARI) Capability Structure
7.6.5. VF TLP Processing Hints (TPH) Capability Structure
7.6.6. VF Address Translation Services (ATS) Capability Structure
7.6.7. VF Access Control Services (ACS) Capability Structure
7.6.2.1. PCI Express* Capability List Register
7.6.2.2. PCI Express* Device Capabilities Register
7.6.2.3. PCI Express* Device Control and Status Register
7.6.2.4. Link Capabilities Register
7.6.2.5. Link Control and Status Register
7.6.2.6. PCI Express* Device Capabilities 2 Register
7.6.2.7. PCI Express* Device Control and Status 2 Register
7.6.2.8. Link Capabilities 2 Register
7.6.2.9. Link Control and Status 2 Register
Visible to Intel only — GUID: mnv1726178382650
Ixiasoft
5.2.2.3.13. PCIe0/PCIe1 VSEC
Parameter | Value | Default Setting | Description |
---|---|---|---|
Vendor Specific Extended Capability | N/A | False | Enables Vendor Specific Extended Capability (VSEC). This parameter serves as an indicator of status of the VSEC enablement in the IP. The value of this parameter become true when you enable the Configuration Extension Bus Interface and specify the next address pointers in the Interfaces tab. |
PF<n> Vendor Specific Extended Capability Offset (where n = 0, 1, 2, 3 ) |
N/A | 0x00000000 | Sets the read-only base address of the 12-bit Vendor Specific Extended Capability offset for PF<n>. This parameter serve as an indicator of next address pointer value in byte-addressing format of the VSEC extended capability. The value of this parameter is shown when you enable the Configuration Extension Bus Interface and specify the next address pointers in the Interfaces tab. |
User ID register from the Vendor Specific Extended Capability | 0x00000000 - 0x0000ffff | 0x00000000 | Sets the read-only value of the 16-bit User ID register from the Vendor Specific Extended Capability. |
Drops Vendor Type0 Messages |
|
False | When selected, received Vendor MSG Type0 is dropped as an Unsupported Request (UR). Otherwise, received Vendor MSG Type0 is not dropped, but visible on AXI4-Stream Receive interface. This option is not applicable for TLP Bypass mode. In TLP Bypass mode, received Vendor MSG Type0 is always visible on AXI4-Stream Receive interface. |
Drops Vendor Type1 Messages |
|
False | When selected, received Vendor MSG Type1 are dropped silently. Otherwise, received Vendor MSG Type1 are not dropped, but visible on AXI4-Stream Receive interface. This option is not applicable for TLP Bypass mode. In TLP Bypass mode, received Vendor MSG Type1 are always visible on AXI4-Stream Receive interface. |