11.3. Use Signal Tap Analyzer for Troubleshooting

The design example provides a pre-defined Signal Tap File (.stp), which is compiled into the design and includes the signals listed in the following table:
After successfully programming the SOF file in the Quartus® Prime Design Software, follow these steps:
  1. Navigate to Tools > Signal Tap Logic Analyzer to launch the Signal Tap Analyzer.
  2. In the User Processing option, select Run Analysis.

The following table lists the debug signals and their descriptions:

Table 59.  Debug Signals
Signals Description Action
Reset Signals
o_rst_ack_n

Active-low asynchronous acknowledgment signal for the i_rst_n reset.

Do not deassert i_rst_n reset until the o_rst_ack_n asserts.

o_tx_rst_ack_n

Active-low asynchronous acknowledgment signal for the i_tx_rst_n reset.

Do not deassert i_tx_rst_n reset until the o_tx_rst_ack_n asserts.

o_rx_rst_ack_n

Active-low asynchronous acknowledgment signal for the i_rx_rst_n reset.

Do not deassert i_rx_rst_n reset until the o_rx_rst_ack_n asserts.

o_src_rs_req Request from GTS Ethernet Hard IP to GTS Reset Sequencer Intel® FPGA IP for reset exit  
o_rx_block_lock Asserted when 66b block alignment is finished on all PCS virtual lanes.  
o_local_fault_status The RX PCS channel has detected a problem that prevents it from being able to receive data.  
o_remote_fault_status The remote link partner has sent remote fault ordered sets indicating that it is unable to receive data.  
rx_lane_current_status Current status of RX reset sequence If the rx_lane_current_status ≠ 0x01 state (operational state), refer to the Debug in Reset Sequence.
tx_lane_current_status Current status of TX reset sequence
o_tx_lanes_stable

Active-high asynchronous status signal for the TX datapath.

Asserts when the TX datapath is ready to send data.

Deasserts when i_tx_rst_n or i_rst_n signal asserts or during the auto-negotiation and link training operation.

 
o_rx_pcs_fully_aligned

Asserted when RX PCS is ready to receive data in PCS66 and PCS Only modes.

o_rx_pcs_ready

Active-high asynchronous status signal for the RX datapath.

Asserts when the RX datapath is ready to send data.

Deasserts when i_rx_rst_n or i_rst_n signal asserts or during the auto-negotiation and link training operation.

Check the CDR lock,0_clk_rec_div64 and o_clk_rec_div and XVIF RX FIFO status (Refer to the GTS Ethernet Hard IP Register Map to access XVIF FIFO Status)
Clock Signals
o_cdr_lock CDR locked

Indicates that the recovered clocks are locked to data.

Do not use o_clk_rec_div64 or o_clk_rec_div until o_cdr_lock is high.

o_sys_pll_locked Verify if the System PLL is locked.

Check if the system PLL output frequency is correct.

Refer to Implement Required Clocking
o_tx_pll_locked Verify that the TX PLL lock is asserted.