Quartus® Prime Pro Edition Settings File Reference Manual

ID 683296
Date 7/08/2024
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

ROUTER_REGISTER_DUPLICATION

Allows the Fitter to automatically duplicate registers within a LAB containing empty logic cells. This option does not alter the functionality of the design. The Auto Register Duplication option is also ignored if you select OFF as the setting for the Logic Cell Insertion -- Logic Duplication logic option. Turning on this option can allow the Logic Cell Insertion -- Logic Duplication logic option to improve a design's routability, but can make formal verification of a design more difficult.

Type

Enumeration

Values

  • Auto
  • Off
  • On

Device Support

  • Arria® 10
  • Cyclone® 10 GX

Notes

This assignment is included in the Fitter report.

Syntax

set_global_assignment -name ROUTER_REGISTER_DUPLICATION <value>

Default Value

Auto