Quartus® Prime Pro Edition Settings File Reference Manual

ID 683296
Date 7/08/2024
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

PERIPHERY_TO_CORE_PLACEMENT_AND_ROUTING_OPTIMIZATION

Specifies whether the Fitter should perform targeted placement and routing optimization on direct connections between periphery logic and registers in the FPGA core. If this option is set to 'Auto', the Fitter will automatically identify transfers with tight timing windows, place the core registers, and route all connections to or from the periphery. These placement and routing decisions are performed before the rest of core placement and routing, ensuring these timing-critical connections can meet timing, and also avoid routing congestion. If this option is set to 'On', all transfers between the periphery and core registers will be optimized, regardless of timing requirements. Setting this option to 'On' globally is not recommended -- instead it is intended for use in the Assignment Editor to force optimization to a targeted set of nodes or entities.

Type

Enumeration

Values

  • Auto
  • Off
  • On

Device Support

  • Arria® 10

Notes

This assignment supports wildcards.

This assignment supports Fitter wildcards.

This assignment is included in the Fitter report.

The value of this assignment must be a node name.

Syntax

set_global_assignment -name PERIPHERY_TO_CORE_PLACEMENT_AND_ROUTING_OPTIMIZATION <value>
set_global_assignment -name PERIPHERY_TO_CORE_PLACEMENT_AND_ROUTING_OPTIMIZATION -entity <entity name> <value>
set_instance_assignment -name PERIPHERY_TO_CORE_PLACEMENT_AND_ROUTING_OPTIMIZATION -to <to> -entity <entity name> <value>

Default Value

OFF