Quartus® Prime Pro Edition Settings File Reference Manual

ID 683296
Date 7/08/2024
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

MINIMUM_SEU_INTERVAL

Specifies the minimum time between two checks of the same bit. Setting to 0 millisecond means check as frequently as possible. Setting to a large value saves power. The unit of interval is millisecond. The maximum allowed interval time is 10000 milliseconds.The actual minimum interval may exceed the value set here and will be reported in Quartus system messages window when you select the generated .sof file as the input to Quartus Programming File Generator or Quartus Programmer.

Type

Integer

Device Support

  • Intel Agilex® 5
  • Intel Agilex® 7
  • Stratix® 10

Notes

None

Syntax

set_global_assignment -name MINIMUM_SEU_INTERVAL <value>
set_instance_assignment -name MINIMUM_SEU_INTERVAL -to <to> <value>

Default Value

10000

Example

set_global_assignment -name MINIMUM_SEU_INTERVAL 300

See Also

CRC_ERROR_CHECKING