4.2. Enabling Error Correction (Internal Scrubbing)

Arria® 10 supports the internal scrubbing feature to automatically scrub away the flipped bit induced by the SEU. To enable the internal scrubbing feature, follow these steps:

  1. On the Assignments menu, click Device.
  2. Click Device and Pin Options and select the Error Detection CRC tab.
  3. Turn on Enable internal scrubbing.
  4. Click OK.