AN 737: SEU Detection and Recovery in Arria® 10 Devices

ID 683064
Date 7/08/2024
Public
Document Table of Contents

6.3.4. Configuring Arria® 10 and Reading .smh File with Fault Injection Debugger

To configure the Arria® 10 with Fault Injection Debugger, perform the following steps:

  1. Launch Fault Injection Debugger from Tools menu.
  2. Make sure a valid programming cable is selected in Hardware Setup.
  3. Click Auto Detect, the windows should display the detected Arria® 10 in the JTAG chain.
  4. Select Arria 10 device, click Select File, select the top.sof from the output_files folder and click Open.
  5. Check the Program/Configure.
  6. Click Start to start the configuration operation.
  7. Right click the Arria 10 device, click Select SMH file.
  8. Select the top.smh from output_files folder and click Open.
  9. Right click the Arria 10 device, click Show Device Sensitivity Map.
  10. SelectASD region(s) - 1 in the Sensitivity Map window as shown in the figure below.
  11. Close the Sensitivity Map window.