6.3.4. Configuring Arria® 10 and Reading .smh File with Fault Injection Debugger
To configure the Arria® 10 with Fault Injection Debugger, perform the following steps:
- Launch Fault Injection Debugger from Tools menu.
- Make sure a valid programming cable is selected in Hardware Setup.
- Click Auto Detect, the windows should display the detected Arria® 10 in the JTAG chain.
- Select Arria 10 device, click Select File, select the top.sof from the output_files folder and click Open.
- Check the Program/Configure.
- Click Start to start the configuration operation.
- Right click the Arria 10 device, click Select SMH file.
- Select the top.smh from output_files folder and click Open.
- Right click the Arria 10 device, click Show Device Sensitivity Map.
- SelectASD region(s) - 1 in the Sensitivity Map window as shown in the figure below.
- Close the Sensitivity Map window.