7.1.2.1. Specify Parameters for the Platform Designer Flow

To specify parameters for your IP core using the Platform Designer flow, follow these steps:
  1. In the Quartus Prime software, create a new Quartus Prime project using the New Project Wizard available from the File menu.
  2. On the Tools menu, click Platform Designer .
    Note: Platform Designer automatically sets device parameters based on your Quartus Prime project settings. To set device parameters manually, use the Device Family tab.
  3. In the IP Catalog, select the available external memory interface IP from the Memory Interfaces and Controllers folder in the Library list. The relevant parameter editor appears.
  4. From the Presets list, select the preset matching your design requirement, and click Apply.
    Tip: If none of the presets match your design requirements, you can apply the closest preset available and then change the inappropriate parameters manually. This method may be faster than entering all the parameters manually, and reduces the chance of having incorrect settings.
  5. Specify the parameters on all tabs.
    Note:
    • For detailed explanation of the parameters, refer to Parameterizing Memory Controllers with UniPHY IP.
    • Although you have applied presets, you may need to modify some of the preset parameters depending on the frequency of operation. A typical list of parameters which you might need to change includes the Memory CAS Latency setting, the Memory CAS Write Latency setting, and the tWTR, tFAW, tRRD, and tRTP settings.
    • For UniPHY-based IP, turn on Generate power-of-2 bus widths for Platform Designer or SOPC Builder on the Controller Settings tab.
    Tip:
    • As a good practice, review any warning messages displayed in the Messages Window and correct any errors before making further changes.
    • To simplify future work, you might want to store the current configuration by saving your own presets. To create, modify, or remove your own custom presets, click New, Update, or Delete at the bottom of the Presets list.
    • If you want to generate an example design for your current configuration, click Example Design at the top-right corner of the parameter editor, specify a path for the example design, and click Ok.
  6. Click Finish to complete the external memory interface IP instance and add it to the system.
    Note: The Finish button may be unavailable until you have corrected all parameterization errors listed in the Messages window.