Intel® VTune™ Profiler

User Guide

ID 766319
Date 12/20/2024
Public
Document Table of Contents

Problem: {Unknown Timer} in the Platform Power Analysis Viewpoint

Platform Power Analysis viewpoint displays an {Unknown Timer} with a blank process name and {Unknown} PID/TID.

Cause

The kernel configuration prevents Intel® VTune™ Profiler from collecting the required data: it cannot identify the PID/TID/module or process name for the timer.

Solution

You may set the CONFIG_TIMER_STAT =Y in the boot configuration file and recompile the kernel.