Agilex™ 7 F-Series and I-Series FPGA Memory Subsystem IP User Guide

ID 789389
Date 7/15/2024
Public
Document Table of Contents

7.4.2.8. Warning_0

Byte offset: 0x00040 (Word32 offset: 0x010).

This indicates the cause of a warning alarm.

Bits Field Access Type Reset Value Description
31 unsupported_cpu_space RW/1C 0x0

1 = an AXI Lite access has been made to an unmapped area of memory.

Write a ‘1’ to clear this bit.
30:6 Unused.      
5 entry_out_of_range RW/1C 0x0

1 = an entry ID has been written to the Entry register that is greater or equal to the ENTRIES parameter.

Write a ‘1’ to clear this bit.
4 unsupported_op_type RW/1C 0x0

1 = an unsupported operation type has been requested using a write to the Mgmt_Ctrl register.

Write a ‘1’ to clear this bit.
3:1 Unused.      
0 Reserved.     Reserved.