To perform a search operation follow these steps through AXI-Lite interface:
  1. Write the key to the MBL_KEY registers.
  2. Poll the MBL_MGMT_CTRL register until the busy bit = 0x0.
  3. Write to the MBL_MGMT_CTRL register:
    • Specifying req_type = 0x3.
    • Specifying tab (logical table).
  4. Check MBL_MGMT_CTRL register success bit, success bit is set to 0x1 to indicate the operation is handled successfully.
  5. Check MBL_RES register for lookup result.
  6. The MBL_KEY_HANDLE register is written with a handle value corresponding to the lookup key.
Figure 49. Lookup Operation Using Key on MBL
  • The address of mbl_mgmt_ctrl register is 0x20.
  • The address of mbl_key_handle is 0x24.
  • The address of key_n register is 0x1000.