3.5. The Required SmartVID QSF Assignments to Compile a Design
If you are creating your own design and want to generate a programming SRAM object file (.sof), you must add the correct SmartVID setting into the Quartus® Prime project for the Agilex™ 7 FPGA development kit to configure successfully. Before you add the following SmartVID setting into the Quartus settings file (.qsf), you must change the configuration scheme to Avalon® streaming interface x8 (AVST x8) for your project. You can also extract the SmartVID setting from the Golden Top file.
set_global_assignment -name VID_OPERATION_MODE "PMBUS MASTER" set_global_assignment -name USE_PWRMGT_SCL SDM_IO0 set_global_assignment -name USE_PWRMGT_SDA SDM_IO12 set_global_assignment -name USE_CONF_DONE SDM_IO16 set_global_assignment -name PWRMGT_BUS_SPEED_MODE "100 KHZ" set_global_assignment -name PWRMGT_SLAVE_DEVICE_TYPE ED8401 set_global_assignment -name PWRMGT_SLAVE_DEVICE0_ADDRESS 47 set_global_assignment -name PWRMGT_SLAVE_DEVICE1_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE2_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE3_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE4_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE5_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE6_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE7_ADDRESS 00 set_global_assignment -name PWRMGT_TRANSLATED_VOLTAGE_VALUE_UNIT VOLTS set_global_assignment -name PWRMGT_PAGE_COMMAND_ENABLE OFF
set_global_assignment -name VID_OPERATION_MODE "PMBUS MASTER" set_global_assignment -name USE_PWRMGT_SCL SDM_IO0 set_global_assignment -name USE_PWRMGT_SDA SDM_IO12 set_global_assignment -name USE_CONF_DONE SDM_IO16 set_global_assignment -name PWRMGT_BUS_SPEED_MODE "100 KHZ" set_global_assignment -name PWRMGT_SLAVE_DEVICE_TYPE OTHER set_global_assignment -name PWRMGT_SLAVE_DEVICE0_ADDRESS 47 set_global_assignment -name PWRMGT_SLAVE_DEVICE1_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE2_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE3_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE4_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE5_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE6_ADDRESS 00 set_global_assignment -name PWRMGT_SLAVE_DEVICE7_ADDRESS 00 set_global_assignment -name PWRMGT_TRANSLATED_VOLTAGE_VALUE_UNIT VOLTS set_global_assignment -name PWRMGT_PAGE_COMMAND_ENABLE OFF