5.5.4. On-Chip I/O Termination in Cyclone® 10 GX Devices

Serial (RS) and parallel (RT) OCT provides I/O impedance matching and termination capabilities. OCT maintains signal quality, saves board space, and reduces external component costs.

The Cyclone® 10 GX devices support OCT in all FPGA I/O banks. For the 3 V I/Os, the I/Os support only OCT without calibration.

Figure 73. Single-ended Termination (RS and RT) This figure shows the single-ended termination schemes supported in Cyclone® 10 GX devices. RT1 and RT2 are dynamic parallel terminations and are enabled only if the device is receiving. In bidirectional applications, RT1 and RT2 are automatically switched on when the device is receiving and switched off when the device is driving.


Table 43.  OCT Schemes Supported in Cyclone® 10 GX Devices
Direction OCT Schemes I/O Type Support
LVDS I/O 3 V I/O
Output RS OCT with calibration Yes
RS OCT without calibration Yes Yes
Input RT OCT with calibration Yes
RD OCT (LVDS I/O standard only) Yes
Bidirectional Dynamic RS and RT OCT Yes No