6.2.2.1. OCT

You require an OCT calibration block if you are using an Agilex™ 7 M-Series FPGA OCT calibrated series, parallel, or dynamic termination for any I/O in your design. There are two OCT blocks in an I/O bank, one for each sub-bank.
  • You must observe the following requirements when using OCT blocks:

    The I/O bank where you place the OCT calibration block must use the same VCCIO_PIO voltage as the memory interface.