Agilex™ 5 ES Device Errata and User Guidelines

ID 825514
Date 12/09/2024
Public
Document Table of Contents

3.2.8. 1913780: Some corrected errors might incorrectly increment ERR0MISC0.CECR or ERR0MISC0.CECO

Description

If a Corrected Error is recorded because of a bus error which has no valid location (ERR0STATUS.MV=0x0), then a subsequent Corrected Error might incorrectly increment either of the ERR0MISC0.CECR or ERR0MISC0.CECO counters.

Conditions

  1. A Corrected Error which has no valid location (ERR0STATUS.MV=0x0) is recorded.
  2. A subsequent Corrected Error occurs.

Impact

The subsequent Corrected Error might improperly increment either of the ERR0MISC0.CECR or ERR0MISC0.CECO counters.

Workaround

No workaround is expected to be required.

Category

Category C