Visible to Intel only — GUID: mtr1422491989775
Ixiasoft
1. Introduction to Intel® FPGA Design Flow for Xilinx* Users
2. Technology Comparison
3. FPGA Tools Comparison
4. Xilinx* to Intel® FPGA Design Conversion
5. Conclusion
6. AN 307: Intel® FPGA Design Flow for Xilinx* Users Archives
7. Document Revision History for Intel® FPGA Design Flow for Xilinx* Users
3.3.1. Project Creation
3.3.2. Design Entry
3.3.3. IP Status
3.3.4. Design Constraints
3.3.5. Synthesis
3.3.6. Design Implementation
3.3.7. Finalize Pinout
3.3.8. Viewing and Editing Design Placement
3.3.9. Static Timing Analysis
3.3.10. Generation of Device Programming Files
3.3.11. Power Analysis
3.3.12. Simulation
3.3.13. Hardware Verification
3.3.14. View Netlist
3.3.15. Design Optimization
3.3.16. Techniques to Improve Productivity
3.3.17. Partial Reconfiguration
3.3.18. Cross-Probing in the Intel® Quartus® Prime Pro Edition Software
4.2.1.2.1. Memory Mode
4.2.1.2.2. Clocking Mode
4.2.1.2.3. Write and Read Operation Triggering
4.2.1.2.4. Read-During-Write Operation at the Same Address
4.2.1.2.5. Error Correction Code (ECC)
4.2.1.2.6. Byte Enable
4.2.1.2.7. Address Clock Enable
4.2.1.2.8. Parity Bit Support
4.2.1.2.9. Memory Initialization
4.2.1.2.10. Output Synchronous Set/Reset
Visible to Intel only — GUID: mtr1422491989775
Ixiasoft
4.3.1.2. SLEW
Equivalent to the SLEW constraint in the Xilinx* Vivado* software, the SLEW_RATE logic option helps to reduce switching noise by controlling low-to-high or high-to-low transitions on output pins. When a large number of output pins switch simultaneously, pins that use the lower SLEW_RATE option help reduce switching noise. This option is only applicable to output or bidirectional pins.
The following example shows how to set the equivalent SLEW constraint to the output “q1”.
Example of XDC command:
# set fast slew rate to q1
set_property SLEW FAST [get_ports q1]
Equivalent QSF command:
# set programmable slew rate to q1
set_instance_assignment -name SLEW_RATE 1 -to q1
For more information about the slew rate feature in the device, refer to the specific device handbook.