2.4.2.3. Output Constraints (set_output_delay)

Output constraints specify all external delays from the device for all output ports in your design.
set_output_delay -clock { clock } -clock_fall -rise -max 2 foo

Use the Set Output Delay (set_output_delay) constraint to specify external output delay requirements. Specify the Clock name (-clock) to reference the virtual or actual clock. When specifying a clock, the clock defines the latching clock for the output port. The Timing Analyzer automatically determines the launching clock inside the device that launches the output data, because all clocks in the device are defined. The following figure is an example of an output delay referencing a virtual clock.

Figure 96. Output Delay Diagram
Figure 97. Output Delay Calculation
Note: Beginning in Quartus® Prime Pro Edition software version 24.3, support for the blackbox argument is removed. You could previously use the blackbox argument to perform delay budgeting on I/Os at the boundary of a design partition. Refer to Deprecation of the blackbox Argument.

You can use the Check Timing (check_timing) command to report problems with a variety of timing constraints, such as the number of output ports that have no output delay constraint.