3.1.3.3.1. Reviewing Reports about Synchronizers

If you implement synchronizers in your design, the Report Asynchronous CDC report identifies the topology that you use. For example, the following figure shows an unconstrained transfer in the Asynchronous CDC Full Report tab.
Figure 199. Unconstrained Transfer in the Asynchronous CDC Full Report Tab


In addition, the CDC Statistics tab presents basic information about the synchronizer, such as the source register and the registers that form the synchronizer.

Figure 200. CDC Statistics Tab Shows Synchronizer Data


The Schematic View tab shows a representation of the synchronizer identified in the crossing.