Intel® Stratix® 10 Device Datasheet

ID 683181
Date 12/08/2023
Public
Document Table of Contents

OCT Calibration Accuracy Specifications

If you enable on-chip termination (OCT) calibration, calibration is automatically performed at power up for I/Os connected to the calibration block.

Table 17.  OCT Calibration Accuracy Specifications for Intel® Stratix® 10 DevicesCalibration accuracy for the calibrated on-chip series termination (RS OCT) and on-chip parallel termination (RT OCT) are applicable at the moment of calibration. When process, voltage, and temperature (PVT) conditions change after calibration, the tolerance may change.
Symbol Description Condition (V) Calibration Accuracy Unit
–E1, –I1 –E2, –I2 –E3, –I3
34-Ω, 48-Ω, 60-Ω, 80-Ω, 120-Ω, and 240-Ω RS Internal series termination with calibration (34-Ω, 48-Ω, 60-Ω, 80-Ω, 120-Ω, and 240-Ω setting) VCCIO = 1.2 ±15 ±15 ±15 %
34-Ω and 40-Ω RS Internal series termination with calibration (34-Ω and 40-Ω setting) VCCIO = 1.5, 1.35, 1.25, 1.2 ±15 ±15 ±15 %
25-Ω and 50-Ω RS Internal series termination with calibration (25-Ω and 50-Ω setting) VCCIO = 1.8, 1.5, 1.2 ±15 ±15 ±15 %
34-Ω, 40-Ω, 48-Ω, 60-Ω, 80-Ω, 120-Ω, and 240-Ω RT Internal parallel termination with calibration (34-Ω, 40-Ω, 48-Ω, 60-Ω, 80-Ω, 120-Ω, and 240-Ω setting) POD12 I/O standard,

VCCIO = 1.2

±15 ±15 ±15 %
48-Ω, 50-Ω, 60-Ω, and 120-Ω RT Internal parallel termination with calibration (48-Ω, 50-Ω, 60-Ω, and 120-Ω setting) VCCIO = 1.5, 1.2 –10 to +60 –10 to +60 –10 to +60 %
48-Ω, 60-Ω, and 120-Ω RT Internal parallel termination with calibration (48-Ω, 60-Ω, and 120-Ω setting) VCCIO = 1.25 –10 to +70 –10 to +70 –10 to +70 %
48-Ω, 60-Ω, and 120-Ω RT Internal parallel termination with calibration (48-Ω, 60-Ω, and 120-Ω setting) VCCIO = 1.35 –10 to +65 –10 to +65 –10 to +65 %
50-Ω RT Internal parallel termination with calibration (50-Ω setting) VCCIO = 1.8 –10 to +50 –10 to +50 –10 to +50 %