Visible to Intel only — GUID: dhs1703035667989
Ixiasoft
1. Introduction
2. Features
3. Getting Started with the AXI Streaming Intel® FPGA IP for PCI Express*
4. IP Architecture and Functional Description
5. AXI Streaming Intel® FPGA IP for PCI Express* Parameters
6. Interfaces and Signals
7. Register Descriptions
8. Document Revision History for the AXI Streaming Intel® FPGA IP for PCI Express* User Guide
A. Specifications
B. Simulating the Design Example
1.1. Goal of the AXI Streaming Intel® FPGA IP for PCI Express* User Guide
1.2. Intended Audience for the AXI Streaming Intel® FPGA IP for PCI Express* User Guide
1.3. What is PCI Express* ?
1.4. What are the Intel® FPGA IPs for PCI Express* ?
1.5. What is the AXI Streaming Intel® FPGA IP for PCI Express* ?
1.6. Example Use Models
1.7. Design Flow Requirements
3.1. Download and Install Quartus Software
3.2. Obtain and Install Intel FPGA IPs and Licenses
3.3. Configure and Generate the AXI Streaming Intel® FPGA IP for PCI Express*
3.4. Instantiate and Connect the AXI Streaming Intel® FPGA IP for PCI Express* Interfaces
3.5. Simulate the AXI Streaming Intel® FPGA IP for PCI Express* IP Variant
3.6. Compile the AXI Streaming Intel® FPGA IP for PCI Express* IP Variant
3.7. Software Drivers for AXI Streaming Intel® FPGA IP for PCI Express* IP Variant
3.8. Build the Application for the AXI Streaming Intel® FPGA IP for PCI Express* IP Variant
3.9. Verification with the AXI Streaming Intel® FPGA IP for PCI Express* IP Variant
3.10. Debugging with the AXI Streaming Intel® FPGA IP for PCI Express* IP Variant
4.1. Clocks and Resets
4.2. PCIe Hard IP (HIP)
4.3. HIP Interface (IF) Adaptor
4.4. Application Error Reporting
4.5. Debug Toolkit and Hard IP (HIP) Reconfiguration Interface
4.6. Configuration Space Extension
4.7. Control Shadow
4.8. Configuration Intercept Interface
4.9. Power Management
4.10. Legacy Interrupt
4.11. Credit Handling
4.12. Completion Timeout
4.13. Transaction Ordering
4.14. Page Request Service (PRS) Events
4.15. TX Non-Posted Metering Requirement on Application
4.16. MSI Pending
4.17. D-State Status
4.18. Configuration Retry Status Enable
4.19. AXI-Streaming Interface
4.20. Precision Time Measurement (PTM) [F/R-Tiles Only]
6.1. Overview
6.2. Clocks and Resets
6.3. Application Packet Interface
6.4. Configuration Extension Bus Interface
6.5. Configuration Intercept Interface
6.6. Function Level Reset Interface
6.7. Control Shadow Interface (st_ctrlshadow)
6.8. Completion Timeout Interface (st_cplto)
6.9. Miscellaneous Signals
6.10. Control and Status Register Responder Interface (lite_csr)
6.11. VF Error Flag Interface (vf_err/sent_vfnonfatalmsg)
6.12. VIRTIO PCI* Configuration Access Interface
6.13. Serial Data Signals
7.3.1.1. AXI Streaming Intel® FPGA IP for PCI Express* Version
7.3.1.2. AXI Streaming Intel® FPGA IP for PCI Express* Features
7.3.1.3. AXI Streaming Intel® FPGA IP for PCI Express* Interface Attributes
7.3.1.4. ERROR GEN CTRL
7.3.1.5. ERROR GEN ATTR
7.3.1.6. ERROR TLP Header DW0-3
7.3.1.7. ERROR TLP Prefix
7.3.1.8. HOT PLUG GEN CTRL
7.3.1.9. POWER MANAGEMENT CTRL
7.3.1.10. LEGACY INTERRUPT CTRL
7.3.1.11. CFG REG IA CTRL
7.3.1.12. CFG REG IA FN NUM
7.3.1.13. CFG REG IA WRDATA
7.3.1.14. CFG REG IA RDDATA
7.3.1.15. PRS CTRL
7.3.1.16. MSI PENDING CTRL
7.3.1.17. MSI PENDING
7.3.1.18. D-STATE STS
7.3.1.19. CFG RETRY CTRL
7.3.3.1. PERFMON CTRL
7.3.3.2. TX MRD TLP
7.3.3.3. TX MWR TLP
7.3.3.4. TX MSG TLP
7.3.3.5. TX CFGWR TLP
7.3.3.6. TX CFGRD TLP
7.3.3.7. RX MRD TLP
7.3.3.8. RX MWR TLP
7.3.3.9. RX MSG TLP
7.3.3.10. RX CFGWR TLP
7.3.3.11. RX CFGRD TLP
7.3.3.12. TX MEM DATA
7.3.3.13. TX CPL DATA
7.3.3.14. RX MEM DATA
7.3.3.15. RX CPL DATA
Visible to Intel only — GUID: dhs1703035667989
Ixiasoft
6.3.5.2.1. Application Logic Guidelines for the AXI Streaming TX Interface in Compact Mode (P/R-Tiles)
Following are the guidelines for the application logic when using the compact packing scheme:
- For a given clock cycle, the header always starts from segment 0, or on the following segment after the end of the previous packet. The header for segment 1 is allowed depending on the utilization for segment 0. Refer to the table below for the allowed conditions. Note that the table does not include all the signals for the AXI-ST TX interface. It only shows the Header (H) and Data (D) combinations to highlight the valid cases where a TLP can be started on segment 1.
- When sending multiple packets on multiple segments in a single clock cycle, the headers must be placed on contiguous segments starting with segment 0. For example, when using a 1024-bit data bus with 4 segments, the header can be on segments 0, 1, 2 but not on segments 0, 1, 3 nor on segments 1, 2, 3.
The following table describes the possible combinations across segments:
The following table describes the possible combinations across segments:
S0 | S1 |
---|---|
H, D | H, D |
H, D | D |
D | H, D |
Example of the compact packing scheme in Gen4x16 with a 512-bit, 2-segment bus on the TX AXI-ST Interface:
1st Command with Data - Payload 16 Bytes
2nd Command with Data - Payload 32 Bytes
3rd Command with Data - Payload 96 Bytes
4th Command with Data – Payload 20 Bytes