MIN_MTBF_REQUIREMENT

Specifies the minimum acceptable Mean Time Between Failures (MTBF), either globally for the design or for a specific synchronizer chain (if applied to the head register of a synchronizer chain). The MTBF value used will be 10 to the power of this setting value, in years. If the MTBF of a synchronizer chain is less than this value, it will be marked as a dangerous, asynchronous transfer that is in need of additional synchronization registers to help avoid metastability.

Type

Integer

Device Support

  • Intel Agilex® 5
  • Intel Agilex® 7
  • Arria® 10
  • Cyclone® 10 GX
  • Stratix® 10

INTEGER_RANGE

-8, 9

Notes

This assignment supports wildcards.

Syntax

set_global_assignment -name MIN_MTBF_REQUIREMENT <value>
set_instance_assignment -name MIN_MTBF_REQUIREMENT -to <to> -entity <entity name> <value>

Default Value

9