Power Distribution Network Design Guidelines: Agilex™ 5 FPGAs and SoCs

ID 813963
Date 11/21/2024
Public
Document Table of Contents

2.3.3. Power Nets and Transient Specifications

Rail transient values provided in the following table are used to design and simulate the board level transient power. Choose the recommended load slew rates and step load at FPGA package ball below for PCB-level PDN system simulations and design. The table shows the maximum tolerable step load at FPGA package pin. The recommended step load is connected to FPGA package ball along with the PCB post-layout model (with decoupling capacitors and voltage regulator model excluding package and silicon/die model) in an EDA tool for time domain simulation to meet rail tolerance of respective power net in the Power Rails Tolerance section at the FPGA package ball.

The table shows for the recommended step load at the package ball and step load’s slew rate.

Note: The step load suggested in the table is for a normal application and worst case operation in FPGA and tiles. The step load can also be scaled down if the dynamic current of the target power rail in PTC is smaller than the step load shown in the table.
Table 7.   Agilex™ 5 Device Family Transient and Step Load Specifications at Package Pin
Package Power Rails At Package Balls (Step Load) DI/dt at Package Balls (for Board Design)-Slew Rate Notes
DI (A)-Step Load DI/dt (A/µs)-Slew Rate

VCC&VCCP

A5E007B

B15A/B23B/B18A

0.8 26 The step load is the worst case step load in the design based on 80% utilization of LAB and clock network.

VCC&VCCP

A5E013B

B23A/B32A/M16A/B23B/B18A

1.5 50 The step load is the worst case step load in the design based on 80% utilization of LAB and clock network.

VCC&VCCP

A5E028B

B23A/B32A/M16A/B23B

2.5 100 The step load is the worst case step load in the design based on 80% utilization of LAB and clock network.

VCC&VCCP

A5E065B

B23A/B32A

3.5 70 The step load is the worst case step load in the design based on 80% utilization of LAB and clock network.

VCC&VCCP

A5E065A

B23A/B32A

3.7 74 The step load is the worst case step load in the design based on 80% utilization of LAB and clock network.

VCC&VCCP

A5D031

B23D/B32B

2 100 The step load is the worst case step load in the design based on 80% utilization of LAB and clock network.

VCC&VCCP

A5D064

B32B

4.9 196 The step load is the worst case step load in the design based on 80% utilization of LAB and clock network.
VCCPT 0.05 7.14
VCCRCORE 0.2 5
VCCIO_PIO 0.645 10.8 Current specification is per I/O bank. Each I/O bank consists of 96 x I/Os. More I/O banks can join the same voltage regulator, but current specification stays per I/O bank.
VCCL_HPS 0.016 0.15
VCCL_HPS_CORE0_CORE1 0.01 0.1
VCCL_HPS_CORE2 0.02 0.2
VCCL_HPS_CORE3 0.014 0.14
VCC_HSSI 0.053 1.66 For X4 GTS transceiver banks
VCCERT_GTS 0.02 2 For single GTS transceiver channel
0.1 0.3 For X4 GTS transceiver channels
VCCEHT_GTS 0.01 0.37 For single GTS transceiver channel
0.07 0.23 For X4 GTS transceiver channels

You must also notice the following:

  1. Step current at package pin is only provided for critical power rails due to either having high current/power profile at die or being highly sensitive. Agilex™ recommends you to do transient/time domain PDN simulation by using this step load for these critical power rails in the Agilex™ 5 Device Family Transient and Step Load Specifications at Package Pin table to ensure you can meet the voltage specification at package pin. If the voltage specification is not met at package pin, decoupling capacitors must be adjusted.
  2. Altera does not provide step current for other power rails not mentioned in the Agilex™ 5 Device Family Transient and Step Load Specifications at Package Pin table. Those power rails are called non-critical power rails due to having less sensitivity or low current profile/power consumption on silicon. Altera does not recommend time domain PDN analysis for non-critical power rails. Non-critical power rails PDN design suggested in this application note is guaranteed.
  3. Altera recommends that you perform DC IR drop analysis for all power rails.