Quartus® Prime Pro Edition User Guide: Platform Designer

ID 683609
Date 9/30/2024
Public
Document Table of Contents

6.2.1. Error Response Slave Parameters

Figure 264. Error Response Slave Parameter Editor


If you turn on Enable CSR Support (for error logging) more parameters become available.

Figure 265.  Error Response Slave Parameter Editor with Enabled CSR Support


Table 133.  Error Response Slave Parameters
Parameter Value Description
AXI master ID width 1-8 bits

Specifies the manager ID width for error logging.

AXI address width 8-64 bits

Specifies the address width for error logging.

This value also affects the overall address width of the system, and should not exceed the maximum address width required in the system.

AXI data width 32, 64, or 128 bits Specifies the data width for error logging.
Enable CSR Support (for error logging) On / Off When turned on, instantiates an Avalon® CSR interface for error logging.
CSR Error Log Depth 1-16 bits Depth of the transaction log, for example, the number of transactions the CSR logs for cycles with errors.
Register Avalon® CSR inputs On / Off When turned on, controls debug access to the CSR interface.