Visible to Intel only — GUID: vrc1613178563723
Ixiasoft
Visible to Intel only — GUID: vrc1613178563723
Ixiasoft
4.3.12. SR-IOV VF Error Flag Interface (Endpoint Only)
The VFs, with no AER support, are required to generate Non-Fatal error messages. The IP does not generate any error message. It is up to the user application logic to generate appropriate messages when specific error conditions occur.
The R-Tile IP for PCIe makes necessary signals available to the user application logic to generate these messages. The Completion Timeout Interface and the signals listed in the table below provide the necessary information to generate Non-Fatal error messages.
This interface applies to EP only.
Signal Name | Direction | Description | EP/RP/BP | Clock Domain |
---|---|---|---|---|
pX_vf_err_poisonedwrreq_s0_o pX_vf_err_poisonedwrreq_s1_o whereX = 0, 1 (IP core number) |
Output | Indicates a Poisoned Write Request is received. | EP | slow_clk |
pX_vf_err_poisonedcompl_s0_o pX_vf_err_poisonedcompl_s1_o whereX = 0, 1 (IP core number) |
Output | Indicates a Poisoned Completion is received. | EP | slow_clk |
pX_vf_err_ur_posted_s0_o pX_vf_err_ur_posted_s1_o whereX = 0, 1 (IP core number) |
Output | Indicates a Posted UR request is received. | EP | slow_clk |
pX_vf_err_ca_postedreq_s0_o pX_vf_err_ca_postedreq_s1_o whereX = 0, 1 (IP core number) |
Output | Indicates a Posted CA request is received. | EP | slow_clk |
pX_vf_err_vf_num_s0_o[10:0] pX_vf_err_vf_num_s1_o[10:0] whereX = 0, 1 (IP core number) |
Output | Indicates the VF number for which the error is detected. | EP | slow_clk |
pX_vf_err_func_num_s0_o[2:0] pX_vf_err_func_num_s1_o[2:0] whereX = 0, 1 (IP core number) |
Output | Indicates the physical function number associated with the VF that has the error. | EP | slow_clk |
pX_vf_err_overflow_o |
Output | Indicates a VF error FIFO overflow and a loss of an error report. The overflow can happen when coreclkout_hip is slower than the default value. If coreclkout_hip is running at the default frequency, the overflow will not happen. | EP | slow_clk |
Signal Name | Direction | Description | EP/RP/BP | Clock Domain |
---|---|---|---|---|
pX_user_sent_vfnonfatalmsg_i whereX = 0, 1 (IP core number) |
Input | Indicates the user application sent a non-fatal error message in response to an error detected. | EP | slow_clk |
pX_user_vfnonfatalmsg_vfnum_i[10:0] whereX = 0, 1 (IP core number) |
Input | Indicates the VF number for which the error message was generated. This bus is valid when user_sent_vfnonfatalmsg_s0_i is high. | EP | slow_clk |
pX_user_vfnonfatalmsg_func_num_i[2:0] whereX = 0, 1 (IP core number) |
Input | Indicates the PF number associated with the VF with the error. This bus is valid when user_sent_vfnonfatalmsg_s0_i is high. | EP | slow_clk |
pX_user_vfnonfatalmsg_ready_o whereX = 0, 1 (IP core number) |
Output | Value 0 indicates an input change is pending. The new value should be held. pX_user_vfnonfatalmsg_ready_o = 1 when the interface is ready to accept the new value. |
EP | slow_clk |