11.1.2. DPRX_RX_STATUS
GXB_BUSY connects to the rx_reconfig_busy input port.
Address: 0x0001
Direction: CRO
Reset: 0x00000000
Bit |
Bit Name |
Function |
---|---|---|
31:21 |
Unused |
|
20 |
FEC_RUNNING_INDICATOR | 8B/10B Channel Coding: Reserved 128B/132B Channel Coding: 0 = FEC is not running 1 = FEC is running |
19 |
FEC_DECODE_DIS_DETECTED | 8B/10B Channel Coding: Reserved 128B/132B Channel Coding: 0 = FEC_DECODE_DIS control link symbol not detected 1 = FEC_DECODE_DIS control link symbol detected |
18 |
FEC_DECODE_EN_DETECTED | 8B/10B Channel Coding: Reserved 128B/132B Channel Coding: 0 = FEC_DECODE_EN control link symbol not detected 1 = FEC_DECODE_EN control link symbol detected |
17 |
GXB_BUSY | 0 = Transceiver not busy 1 = Transceiver busy |
16 |
SYNC_LOSS | This flag can be reset by writing it to 1: 0 = Symbol lock on all lanes in use 1 = Symbol lock lost on one or more of the used lanes |
15:9 |
Unused |
|
8 | INTERLANE_ALIGN | 0 = Inter-lane alignment not achieved 1 = Inter-lane alignment achieved |
7 |
SYM_LOCK3 | 0 = Symbol unlocked (lane 3) 1 = Symbol locked (lane 3) |
6 |
SYM_LOCK2 | 0 = Symbol unlocked (lane 2) 1 = Symbol locked (lane 2) |
5 |
SYM_LOCK1 | 0 = Symbol unlocked (lane 1) 1 = Symbol locked (lane 1) |
4 |
SYM_LOCK0 | 0 = Symbol unlocked (lane 0) 1 = Symbol locked (lane 0) |
3 |
CR_LOCK3 | 0 = Clock unlocked (lane 3) 1 = Clock locked (lane 3) |
2 |
CR_LOCK2 | 0 = Clock unlocked (lane 2) 1 = Clock locked (lane 2) |
1 |
CR_LOCK1 | 0 = Clock unlocked (lane 1) 1 = Clock locked (lane 1) |
0 |
CR_LOCK0 | 0 = Clock unlocked (lane 0) 1 = Clock locked (lane 0) |