Arria® V Device Datasheet

ID 683022
Date 5/23/2023
Public
Document Table of Contents

1.1.1.3.3. HPS Power Supply Operating Conditions

Table 5.  HPS Power Supply Operating Conditions for Arria® V SX and ST DevicesThis table lists the steady-state voltage and current values expected from Arria® V system-on-a-chip (SoC) devices with Arm* -based hard processor system (HPS). Power supply ramps must all be strictly monotonic, without plateaus. Refer to Recommended Operating Conditions for Arria® V Devices table for the steady-state voltage values expected from the FPGA portion of the Arria® V SoC devices.
Symbol Description Condition Minimum 7 Typical Maximum7 Unit
VCC_HPS HPS core voltage and periphery circuitry power supply –C4, –I5, –C5, –C6 1.07 1.1 1.13 V
–I3 1.12 1.15 1.18 V
VCCPD_HPS 8 HPS I/O pre-driver power supply 3.3 V 3.135 3.3 3.465 V
3.0 V 2.85 3.0 3.15 V
2.5 V 2.375 2.5 2.625 V
VCCIO_HPS HPS I/O buffers power supply 3.3 V 3.135 3.3 3.465 V
3.0 V 2.85 3.0 3.15 V
2.5 V 2.375 2.5 2.625 V
1.8 V 1.71 1.8 1.89 V
1.5 V 1.425 1.5 1.575 V
1.35 V 9 1.283 1.35 1.418 V
1.2 V 1.14 1.2 1.26 V
VCCRSTCLK_HPS HPS reset and clock input pins power supply 3.3 V 3.135 3.3 3.465 V
3.0 V 2.85 3.0 3.15 V
2.5 V 2.375 2.5 2.625 V
1.8 V 1.71 1.8 1.89 V
VCCPLL_HPS HPS PLL analog voltage regulator power supply 2.375 2.5 2.625 V
VCC_AUX_SHARED HPS auxiliary power supply 2.375 2.5 2.625 V
7 The power supply value describes the budget for the DC (static) power supply tolerance and does not include the dynamic tolerance requirements. Refer to the PDN tool for the additional budget for the dynamic tolerance requirements.
8 VCCPD_HPS must be 2.5 V when VCCIO_HPS is 2.5, 1.8, 1.5, or 1.2 V. VCCPD_HPS must be 3.0 V when VCCIO_HPS is 3.0 V. VCCPD_HPS must be 3.3 V when VCCIO_HPS is 3.3 V.
9 VCCIO_HPS 1.35 V is supported for HPS row I/O bank only.