This table lists the internal clock frequency specification for the AS configuration scheme. The DCLK frequency specification applies when you use the internal oscillator as the configuration clock source. The AS multi-device configuration scheme does not support DCLK frequency of 100 MHz.

Parameter Minimum Typical Maximum Unit
DCLK frequency in AS configuration scheme 5.3 7.9 12.5 MHz
10.6 15.7 25.0 MHz
21.3 31.4 50.0 MHz
42.6 62.9 100.0 MHz