4.3. Controlling the On-board Clock through Clock Controller GUI
The Clock Controller GUI can control the outputs of on-board Si5391-1/Si5391-2/Si5392/ Si5395/Si5332/Si5518. The instructions to run Clock Controller GUI are stated in the Running the BTS GUI. You can also start it using the BTS GUI icon Clock.
The Clock Controller communicates with the System MAX® 10 device through 10-pin JTAG header, J7 or USB port, J1. Then, the System MAX® 10 controls the programmable clock part through a 2-wire I2C bus.
Note: You cannot run the stand-alone Clock Controller GUI application when the BTS or Power Monitor GUI is running at the same time.
Note: Si5518 can be controlled only when a design in which the SPI interface is instantiated, such as the bts_config.sof under the board_test_system\image\ES folder that has been downloaded to the FPGA.