Visible to Intel only — GUID: aln1685713677444
Ixiasoft
1. Answers to Top FAQs
2. Network-on-Chip (NoC) Overview
3. Hard Memory NoC in Intel Agilex® 7 M-Series FPGAs
4. NoC Design Flow in Intel® Quartus® Prime Pro Edition
5. NoC Real-time Performance Monitoring
6. Simulating NoC Designs
7. NoC Power Estimation
8. Hard Memory NoC IP Reference
9. Document Revision History of Intel Agilex® 7 M-Series FPGA Network-on-Chip (NoC) User Guide
4.4.1. General NoC IP Connectivity Guidelines
4.4.2. Connectivity Guidelines: NoC Initiators for Fabric AXI4 Managers
4.4.3. Connectivity Guidelines: NoC Targets for Fabric AXI4 Managers
4.4.4. Connectivity Guidelines: NoC Clock Control
4.4.5. Connectivity Guidelines: NoC Initiators for HPS
4.4.6. Connectivity Guidelines: NoC Targets for HPS
6.1. Adding NoC Connectivity and Address Mapping to the Simulation Netlist
6.2. Generating a Simulation Registration Include File (NoC Assignment Editor Connection Flow)
6.3. Generating a Simulation Registration Include File (Platform Designer Connection Flow)
6.4. Contents of Simulation Registration Include File
8.1.2.1. NoC Initiator Intel FPGA IP AXI4/AXI4 Lite Interfaces
8.1.2.2. NoC Initiator AXI4 User Interface Signals
8.1.2.3. NoC Initiator Intel FPGA IP AXI4 Lite User Interface Signals
8.1.2.4. NoC Initiator Intel FPGA IP Clock and Reset Signals
8.1.2.5. NoC Initiator Intel FPGA IP Platform Designer-Only Signals
Visible to Intel only — GUID: aln1685713677444
Ixiasoft
4.3.1. NoC Initiators for Hard Processor Systems
Configure NoC initiators for hard processor systems (HPS) using the Hard Processor System Intel Agilex 7 / Agilex 9 FPGA IP. To enable NoC initiators for HPS when parameterizing the Hard Processor System Intel Agilex 7 / Agilex 9 FPGA IP, follow these steps:
- Click the SDRAM tab in the IP Parameter Editor.
- Turn on the Enable HPS-to-HNOC-INIU AXI Interfaces option.
- Select one of the following HNOC Interface Configuration options:
- Single-Channel—this configuration instantiates one initiator in the MPFE. Select Single-Channel configuration for memory capacity up to 64 GB when you do not require interleaving.
- Dual-Channel—this configuration instantiates two initiators in the MPFE. You can also turn on the Enable Interleave Mode option to enable logic in the MPFE to interleave between the HPS-EMIF channels. Select Dual-Channel configuration for memory capacity above 64 GB or when enabling interleaving.
Figure 19. SDRAM Tab of Hard Processor System Intel Agilex 7 / Agilex 9 FPGA IP Parameter Editor
NoC initiators for HPS can only connect to NoC targets in External Memory Interfaces for HPS Intel FPGA IP. For further information on HPS, refer to the Intel Agilex 7 Hard Processor System Component Reference Manual.
Related Information