Visible to Intel only — GUID: jhg1513040271858
Ixiasoft
4.4.2. Receiver Input Return Loss
The differential input return loss, in dB, of the receiver must follow Equation 14, with f being the frequency in GHz. The reference impedance for the differential return loss measurement is 100 Ω.
The differential to common-mode return loss, in dB, of the receiver must follow the equation below.
Figure 25. Receiver Differential to Common-mode Return Loss Limit for 29 Gsym/s
Equation 14. Differential to Common-Mode Return Loss