Visible to Intel only — GUID: exd1565894721567
Ixiasoft
1.1. Compilation Overview
1.2. Using the Node Finder
1.3. Design Analysis & Elaboration
1.4. Design Synthesis
1.5. Design Place and Route
1.6. Incremental Optimization Flow
1.7. Fast Forward Compilation Flow
1.8. Full Compilation Flow
1.9. HSSI Dual Simplex IP Generation Flow
1.10. Exporting Compilation Results
1.11. Integrating Other EDA Tools
1.12. Compiler Optimization Techniques
1.13. Compilation Monitoring Mode
1.14. Synthesis Language Support
1.15. Synthesis Settings Reference
1.16. Fitter Settings Reference
1.17. Design Compilation Revision History
1.4.3.1. Registering the SDC-on-RTL SDC File
1.4.3.2. Applying the SDC-on-RTL Constraints
1.4.3.3. Inspecting SDC-on-RTL Constraints
1.4.3.4. Creating Constraints in SDC-on-RTL SDC Files
1.4.3.5. Using Entity-Based SDC-on-RTL Constraints
1.4.3.6. Types of SDC Files Used in the Quartus® Prime Software
1.4.3.7. Example: Using SDC-on-RTL Features
1.10.1. Exporting a Version-Compatible Compilation Database
1.10.2. Importing a Version-Compatible Compilation Database
1.10.3. Creating a Design Partition
1.10.4. Exporting a Design Partition
1.10.5. Reusing a Design Partition
1.10.6. Viewing Quartus Database File Information
1.10.7. Clearing Compilation Results
1.12.1. Compiler Optimization Modes
1.12.2. Precompiled Component (PCC) Generation Stage
1.12.3. Compilation on a Compute Farm
1.12.4. Allow Register Retiming
1.12.5. Automatic Gated Clock Conversion
1.12.6. Enable Intermediate Fitter Snapshots
1.12.7. Fast Preserve Option
1.12.8. Fractal Synthesis Optimization
2.1. Factors Affecting Compilation Results
2.2. Strategies to Reduce the Overall Compilation Time
2.3. Reducing Synthesis Time and Synthesis Netlist Optimization Time
2.4. Reducing Placement Time
2.5. Reducing Routing Time
2.6. Reducing Static Timing Analysis Time
2.7. Setting Process Priority
2.8. Reducing Compilation Time Revision History
Visible to Intel only — GUID: exd1565894721567
Ixiasoft
1.6.2.1.4. Validating Timing Constraints with Snapshot Viewer
- To run the Plan or Place stage of the Fitter, double-click the stage in the Compilation Dashboard.
- After the stage completes, click the Snapshot Viewer icon for that stage in the Compilation Dashboard. The Snapshot Viewer opens.
- Under Validate Constraints, double-click Timing Exceptions. The Timing Exception Results report opens, allowing additional analysis and locating to other tools.
Figure 89. Validate Constraints—Timing Exceptions Report
- Under Validate Constraints, double-click Check Unregistered Ports.
Figure 90. Validate Constraints—Check Unregistered Ports Report