Visible to Intel only — GUID: qxs1674511444610
Ixiasoft
Visible to Intel only — GUID: qxs1674511444610
Ixiasoft
5.3.6.2. Initialization Protocol (Device Discovery)
You must configure the NAND Flash controller according to the type and characteristics of the NAND Flash device you are connecting. To do this, you can use the device discovery mechanism which is supported by the NAND Flash controller. The device discovery mechanism is an initialization protocol that automatically detects what kind of Flash device is connected and minimally configures the controller to perform simple data transfers (disabling ECC, cache, multiplane, and multi-LUN operations and setting timing parameters to the maximum values).
During the device discovery process, the controller classifies the NAND Flash device using the categories shown in the following table.
Type of Device | Details | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
ONFI | Support Read ID (with address 0x20 and 0x00), READ PARAMETER PAGE, and CHANGE READ Column with 2 address bytes commands. | |||||||||
Toggle | Support Read ID (with address 0x40 and 0x00), READ PARAMETER PAGE and CHANGE READ Column with 2 address bytes commands. The NAND Flash controller can handle memories with both 256 bytes and 512 bytes parameter page. When this mode is detected, the controller automatically switches PHY logic to utilize values provided in the phy_*_reg signals (see Device Discovery interface in 4.3.5 Signals Description section). The following signals in the system manager must be set with the appropriate value. See the description of the PHY registers in the NAND Flash Controller Programming Model section.
|
|||||||||
Legacy | Support for READ ID command with address 0x00 is required. Only a few predefined memory types are supported. Additionally, the dd_* signals are used to fetch information missing in READ ID command (see Device Discovery Interface). |
|||||||||
Unrecognized | In case of unrecognized devices, the controller uses the dd_* signals to read required configuration (see the Device Discovery Interface section). The controller outputs the value returned by NAND Flash device on READ ID command with address 0x00 on the dd_id_value signal together with asserting the dd_req signal. Then it expects logical 1 on the dd_ack signal asserted together with values of page size (dd_page_size signal), number of pages per block (dd_pages_per_block), field selecting the number of the row address bytes (dd_row_addr_width), flag selecting the 16 bit DQ bus on the Flash interface (dd_support_16_bit_en), number of LUN-es in single NAND Flash device (dd_lun_number). |
The device discovery process can be divided into the following phases:
- Phase 1: Waiting for NAND flash device to be ready after power-on. The controller waits for RB_valid_Vcc time (from NAND flash device specification) which is defined with rb_valid_time signal. After this time, the controller checks for dfi_rbn[0] signal (in DFI interface) and waits until it is set to 1. This indicates that the NAND flash memory device is ready for the next phase of initialization process.
- Phase 2: Sending RESET command (0xFF) to the NAND Flash memory device and waiting to finish processing this command. After this, if the discovery_inhibit signal is set to 1, the controller is configured with values provided on the dd_* signals and the initialization process is finished. Otherwise, the next phase is executed.
- Phase 3: Detecting memory type with READ ID command.
- The controller sends the READ ID command with the 0x20 address and tries to read the ONFI signature.
- If the signature is not correct it sends the READ ID command with 0x40 address to detect the JEDEC signature.
- If the signature is still not correct, the controller sends the READ ID command with the 0x00 address to detect legacy device.
- If the signature is still unknown, the controller classifies the connected devices as “unrecognized device”
A RESET command is sent between each one of the READ ID commands to ensure that NAND Flash memory device is not in a unknown state.
- Phase 4: Reading NAND Flash device parameters and setting control registers of the controller.
Depending on the device type classification in the previous phase, the controller reads NAND Flash memory parameters value based on:
- Value of READ ID command with 0x00 address for all types of devices.
- Value of Parameter page for ONFI and Toggle devices only.
- Values provided on dd_* signals for unrecognized devices.
When the initialization finishes, the controller indicates this by asserting the init_comp output signal and setting the init_comp bit in ctrl_status(0x0118) register.
If the device discovery mechanism finishes with a failure, the NAND Flash controller sets a value of 0x0 to the dd_id_value signal along with the assertion of the dd_req signal. The controller then expects a logical 1 on the dd_ack pin which should be asserted along with the default values set in the dd_page_size, dd_pages_per_block, dd_row_addr_width, dd_support_16_bit_en, and dd_lun_number signals coming from the system manager.
The minimum configuration required by the controller to perform any transfer operation is shown in the following table.
Register in NAND Flash Controller | Field in Register |
---|---|
transfer_cfg_1 (0x0404) | Set value of sector_size and last_sector_size fields that define the size of the main area in a NAND Flash page. |
nf_dev_layout (0x0424) | Set the value of PPB (pages per block) in the NAND Flash device. |
device_ctrl (0x0430) | Set value of row_addr_width field to select the number of row address bytes supported in the NAND Flash device. |
common_settings (0x1008) | Set value in device_16bit field for 16-bit NAND Flash devices. |
If the device discovery mechanism is disabled (with discovery_inhibit signal set to 1), the host must program the previous registers before executing any NAND command.
Additionally to the configuration provided by the device discovery mechanism under success scenario, the controller may fill the reset of the registers described in the following table. The following table also describes how the register fields are obtained.
Use this key to understand the fields in the table.
- ID: Value obtained with the READ ID command.
- PP: Value obtained with the READ PARAMETER PAGE command.
- SysMgr: System manager signals in the device discovery interface.
- X: Value not available for this type of memory.
Register Name | ONFI | Toggle | Legacy | Unrecognized |
---|---|---|---|---|
transfer_cfg_1 (0x0404) |
PP | PP | ID | SysMgr |
nf_dev_layout (0x0424) | PP – Only PPB and LN fields | PP – Only PPB and LN fields | ID, SysMgr - Only PPB and LN fields | SysMgr - Only PPB and LN fields |
device_ctrl (0x0430) | PP – Only row_addr_width field | PP – Only row_addr_width field | SysMgr - Only row_addr_width field | SysMgr - Only row_addr_width field |
common_settings (0x1008) | PP – Only device_16bit field | PP – Only device_16bit field | ID – Only device_16bit field | SysMgr – Only device_16bit field |
manufacturer_id (0x0808) | ID | ID | ID | ID |
nf_device_areas (0x080c) | PP | PP | ID -spare_area_size not available |
SysMgr - spare_area_size not available |
device_params_0 (0x0810) | ID and PP | ID and PP | ID – only device_type available |
ID and SysMgr - plane_addr_bits and bits_per_cell not available |
device_params_1 (0x0814) | ID | ID | X | X |
device_features (0x0818) | PP | PP | X | X |
device_blocks_per_lun (0x081c) | PP | PP | X | X |
device_revision (0x0820) | PP | PP | X | X |
onfi_timing_modes_0 (0x0824) | PP | X | X | X |
onfi_timing_modes_1 (0x0828) | PP | X | X | X |
onfi_iterlv_op_attr (0x082c) | PP | X | X | X |
onfi_sync_opt_0 (0x0830) | PP | X | X | X |
onfi_sync_opt_1 (0x0834) | PP | X | X | X |