Cyclone V Device Datasheet

ID 683801
Date 5/23/2023
Public
Document Table of Contents

Recommended Operating Conditions

Table 4.  Recommended Operating Conditions for Cyclone® V DevicesThis table lists the steady-state voltage values expected from Cyclone® V devices. Power supply ramps must all be strictly monotonic, without plateaus.
Symbol Description Condition Minimum 2 Typical Maximum2 Unit
VCC Core voltage, periphery circuitry power supply, transceiver physical coding sublayer (PCS) power supply, and transceiver PCI Express* ( PCIe* ) hard IP digital power supply Devices without internal scrubbing feature 1.07 1.1 1.13 V
Devices with internal scrubbing feature (with SC suffix) 3 1.12 1.15 1.18 V
VCC_AUX Auxiliary supply 2.375 2.5 2.625 V
VCCPD 4 I/O pre-driver power supply 3.3 V 3.135 3.3 3.465 V
3.0 V 2.85 3.0 3.15 V
2.5 V 2.375 2.5 2.625 V
VCCIO I/O buffers power supply 3.3 V 3.135 3.3 3.465 V
3.0 V 2.85 3.0 3.15 V
2.5 V 2.375 2.5 2.625 V
1.8 V 1.71 1.8 1.89 V
1.5 V 1.425 1.5 1.575 V
1.35 V 1.283 1.35 1.418 V
1.25 V 1.19 1.25 1.31 V
1.2 V 1.14 1.2 1.26 V
VCCPGM Configuration pins power supply 3.3 V 3.135 3.3 3.465 V
3.0 V 2.85 3.0 3.15 V
2.5 V 2.375 2.5 2.625 V
1.8 V 1.71 1.8 1.89 V
VCCA_FPLL 5 PLL analog voltage regulator power supply 2.375 2.5 2.625 V
VCCBAT 6

Battery back-up power supply

(For design security volatile key register)

1.2 3.0 V
VI DC input voltage –0.5 3.6 V
VO Output voltage 0 VCCIO V
TJ Operating junction temperature Commercial 0 85 °C
Industrial –40 100 °C
Automotive –40 125 °C
tRAMP 7 Power supply ramp time Standard POR 200µs 100ms
Fast POR 200µs 4ms
2 The power supply value describes the budget for the DC (static) power supply tolerance and does not include the dynamic tolerance requirements. Refer to the PDN tool for the additional budget for the dynamic tolerance requirements.
3 The SEU internal scrubbing feature is available for Cyclone V E, GX, SE, and SX devices with the "SC" suffix in the part number. For device availability and ordering, contact your local Intel sales representatives.
4 VCCPD must be 2.5 V when VCCIO is 2.5, 1.8, 1.5, 1.35, 1.25, or 1.2 V. VCCPD must be 3.0 V when VCCIO is 3.0 V. VCCPD must be 3.3 V when VCCIO is 3.3 V.
5 PLL digital voltage is regulated from VCCA_FPLL.
6 If you do not use the design security feature in Cyclone® V devices, connect VCCBAT to a 1.5-V, 2.5-V, or 3.0-V power supply. Cyclone® V power-on reset (POR) circuitry monitors VCCBAT. Cyclone® V devices do not exit POR if VCCBAT is not powered up.
7 This is also applicable to HPS power supply. For HPS power supply, refer to tRAMP specifications for standard POR when HPS_PORSEL = 0 and tRAMP specifications for fast POR when HPS_PORSEL = 1.