Stratix® V Device Handbook: Volume 1: Device Interfaces and Integration

ID 683665
Date 10/18/2023
Public
Document Table of Contents

5.8.1. Single-ended I/O Termination

Voltage-referenced I/O standards require an input VREF and a termination voltage (VTT). The reference voltage of the receiving device tracks the termination voltage of the transmitting device.

The supported I/O standards such as SSTL-12, SSTL-125, SSTL-135, and SSTL-15 typically do not require external board termination.

Intel recommends that you use OCT with these I/O standards to save board space and cost. OCT reduces the number of external termination resistors used.

Note: You cannot use RS and RT OCT simultaneously. For more information, refer to the related information.
Figure 102. SSTL I/O Standard TerminationThis figure shows the details of SSTL I/O termination on Stratix® V devices. This is not applicable for SSTL-12, SSTL-15, SSTL-125, and SSTL-135 I/O standards.


Figure 103. HSTL I/O Standard TerminationThis figure shows the details of HSTL I/O termination on the Stratix® V devices. This is not applicable for HSUL-12 I/O standard.