3.5.4. Multipliers

A single variable precision DSP block can perform many multiplications in parallel, depending on the data width of the multiplier.

There are two multipliers (upper multiplier and bottom multiplier) per variable precision DSP block. You can configure these two multipliers in several operational modes:

  • One 27 x 27 multiplier
  • Two 18 x 18 multipliers