5.7.5. LVDS Input RD OCT in Stratix V Devices

The Stratix® V devices support RD OCT in all I/O banks.

You can only use RD OCT if you set the VCCPD to 2.5 V.

Figure 96. Differential Input OCT

The Stratix® V devices support OCT for differential LVDS input buffers with a nominal resistance value of 100  Ω, as shown in this figure.