Agilex™ 7 Power Distribution Network Design Guidelines

ID 683393
Date 10/18/2024
Public
Document Table of Contents

4.3. F-Tile Rail Board Connection and LC Filter Recommendation under Noisy Voltage Regulator

The LC filter recommendation in this chapter is not required for the F-Tile power rails if you meet the voltage regulator (VR) ripple requirement in the Maximum Ripple Requirements for the F-Tile Analog Power Rails table. Altera recommends using the LTC7151S voltage regulator to meet very tight noise specifications for VCCERT1_FHT_GXF and VCCERT2_FHT_GXF. You can use any other voltage regulators for the F-Tile power rails as long as you meet the voltage regulator ripple specifications by selecting a proper voltage regulator. If you do not meet the VR ripple specification in the Maximum Ripple Requirements for the F-Tile Analog Power Rails table by using a noisy voltage regulator, Altera recommends using the LC filters in this chapter to block the high noise. Implement one set of LC filters for each tile on the FPGA.

Table 22.   Maximum Ripple Requirements for the F-Tile Analog Power Rails
Power Rail Maximum Ripple (mVp-p)
VCCERT_FGT_GXF 5
VCCERT1_FHT_GXF 5
VCCERT2_FHT_GXF 5
VCCH_FGT_GXF 7
VCCEHT_FHT_GXF 7
Figure 25. Filter Recommendation for VCCH_FGT_GXF per Tile
Figure 26. Filter Recommendation for VCCCLK_GXF per Tile