Visible to Intel only — GUID: wks1504195318546
Ixiasoft
Visible to Intel only — GUID: wks1504195318546
Ixiasoft
10.2.1.4.2. NPDME PLL and Channel Commands
These commands use the Native PHY and channel PLL NPDME master ports to read and write registers in the ATX PLL, fPLL, and Native PHY transceiver channels.
Command | Description |
---|---|
adme_read32 <slave_if> <reg_addr> | Performs a 32-bit read from the slave interface of the register address specified. |
adme_read8 <slave_if> <reg_addr> | Performs an 8-bit read from the slave interface of the register address specified. |
adme_write32 <slave_if> <reg_addr> <value> | Performs a 32-bit write of the value specified to the slave interface and register specified |
adme_write8 <slave_if> <reg_addr> <value> | Performs an 8-bit write of the value specified to the slave interface and register specified |
adme_rmw32 <slave_if> <reg_addr> <bit_mask> <value> | Performs a 32-bit read-modify-write to the slave interface at the register address using the bit mask specified. |
adme_rmw8 <slave_if> <reg_addr> <bit_mask> <value> | Performs an 8-bit read-modify-write to the slave interface at the register address using the bit mask specified. |
adme_dump_to_file <slave_if> <filename> <start_addr> <end_addr> | Writes the contents of the slave interface to the file specified. The start and end register addresses specify the range of the write. The <slave_if> argument can have the following values:
|
atxpll_check | Checks the ATX PLL lock and calibration status |
fpll_check | Checks the fPLL lock and calibration status |
channel_check | Checks each channel clock data recovery (CDR) lock status and the TX and RX calibration status |
NPDME Command Examples
The following PLL commands use the addresses specified below in the Register Address Map.
Use the following command to read the value register address 0x480 in the ATX PLL:
% adme_read8 $atxpll_adme 0x480
Use the following command to write 0xFF to register address 0x4E0 in the fPLL:
% adme_write8 $fpll_adme 0x4E0 0xFF
Use the following command to perform a read-modify-write to write register address 0x02 in channel 3:
% adme_rmw8 $channel_adme(3) 0x03 0x02
Use the following command to save the register values from 0x100-0x200 from the ATX PLL to a file:
% adme_dump_to_file $atxpll <directory_path>atx_regs.txt 0x100 0x200