PHY Lite for Parallel Interfaces Intel® FPGA IP User Guide

ID 683716
Date 8/02/2023
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

5.5.6.4.6. Internal FPGA Path Timing Violation

If timing violations are reported at the internal FPGA paths (such as <instance_name>_usr_clk or <instance_name>_phy_clk_*), consider the following guidelines:

If setup time violation is reported, lower the clock rate of the user logic from full-rate to half-rate, or from half-rate to quarter-rate. This reduces the frequency requirement of the IP core-to-core data transfer.

If hold time violation is observed, you may increase hold uncertainty value to equal or higher than the violation amount in the .sdc file. This will provide a more stringent constraint during design fitting. Following is an example to increase the hold uncertainty.
If {$::quartus(nameofexecutable) != “quartus_sta”}{

	set_clock_uncertainty -from [<instance_name>_phy_clk_*] -to [<instance_name>_phy_clk_*] -hold 0.3 -add

	set_clock_uncertainty -from [<instance_name>_usr_clk] -to [<instance_name>_usr_clk] -hold 0.3 -add

}

However, increasing the hold uncertainty value may cause setup timing violation at slow corner.